    Brand Name : GENY
    Model Number : YC1893/1D
    Certification : ISO, CE
    Price : negotiation
    Payment Terms : L/C,T/T,D/P
    Supply Ability : 30 PCS per month
    Delivery Time : 30 days after order confirmed
    • Product Details
    • Company Profile

    Multi-station Meter Test Bench

    Multi-station Meter Test Bench


    Applications


    1. Nation-level utility companies

    2. Governmental bureaus of metrology

    3. Big energy meter manufacturers



    Specifications


    single - phase



    YC1891D-6

    YC1891D-12

    YC1891D-24

    YC1891D-48

    Number of meter positions

    6

    12

    24

    48

    Accuracy

    0.05

    Power Source

    YCS-101-250

    YCS-101-600

    YCS-101-1200

    YCS-101-2500

    Standard Meter

    SZ01A-K3

    MSVT

    HJ200GL-6

    HJ200GL-12

    HJ200GL-24

    HJ200GL-48

    QCD

    D5 series

    Scanning Head

    YCG-2 series

    Voltage

    Test voltage output

    24V – 288V or customized

    Power of the voltage output

    100VA

    250VA

    500VA

    1000VA

    Resolution

    Better than 0.01% of full scale value of range

    Setting accuracy

    Better than 0.05% at the final range value

    Stability

    Better than 0.005%/h (integration time 150 s)

    Load regulation from 0-max. load

    Better than 0.01%

    Distortion factor

    Better than 0.3% for linear resistance load

    Harmonics

    2nd – 21st free programmable

    Current

    Test current output

    1mA – 100A or customized,Max.200A

    1mA – 100A

    Power of the current output

    150VA

    350VA

    750VA

    1500VA

    Resolution

    Better than 0.01% of full scale value of range

    Setting accuracy

    Better than 0.05% at the final range value

    Stability

    Better than 0.005%/h (integration time 150 s)

    Load regulation from 0-max. load

    Better than 0.01%

    Distortion factor

    Better than 0.3% for linear resistance load

    Harmonics

    2nd – 21st free programmable

    Phase angle

    Range

    0 -- 360°

    Resolution

    0.01°

    Setting accuracy

    0.1°

    Frequency

    Range

    45Hz – 65Hz

    Resolution

    0.01Hz

    Error display

    Type of error display

    Red LED

    Resolution of the error displays

    8 digits


    Voltage Supply

    220V±10% or customized

    50/60Hz±2Hz

    3x220/380V±10% or customized

    50/60Hz±2Hz

    Ambient temperature

    -10°C -- +40°C

    Relative humidity

    35% -- 85%


    Three-Phase



    Technical spec.

    YC1893D-6

    YC1893D-12

    YC1893D-24

    YC1893D-48

    Number of meter positions

    6

    12

    24

    48

    Accuracy

    0.05 / 0.02

    Power Source

    YCS-103-250

    YCS-103-600

    YCS-103-1200

    YCS-103-2500

    Standard Meter

    SZ03A-K6 / SZ03A-K8

    Scanning Head

    YCG-S Series

    Voltage


    Test voltage output(Phase-Neutral)

    3x(24V~288V)(or customized)

    Power of the voltage output

    Max. 3x100VA

    Max. 3x250VA

    Max. 3x500VA

    Max. 3x1000VA

    Resolution

    Better than 0.01% of full scale value of range

    Setting accuracy

    Better than 0.05% at the final range value

    Stability

    Better than 0.005% /h (integration time 150s)

    Load regulation from 0~max. load

    Better than 0.01%

    Distortion factor

    Better than 0.3% for linear resistance load

    Harmonic

    2nd~21st free programmable

    Current


    Test current output

    3x(1mA~100A)

    Power of the current output

    Max. 3x150VA

    Max. 3x350VA

    Max. 3x750VA

    Max. 3x1500VA

    Resolution

    Better than 0.01% of full scale value of range

    Setting accuracy

    Better than 0.05% at the final range value

    Stability

    Better than 0.005% /h (integration time 150s)

    Load regulation from 0~max. load

    Better than 0.01%

    Distortion factor

    Better than 0.3% for linear resistance load

    Harmonic

    2nd~21st free programmable

    Phase angle


    Range

    0~360⁰

    Resolution

    0.01⁰

    Setting accuracy

    0.1⁰

    Frequency


    Range

    45Hz~65Hz

    Resolution

    0.01Hz

    Error display


    Type of error display

    Red LED

    Resolution of error displays

    8 digitals

    Other


    Voltage supply

    3x220/380V±10%(or customized)

    50/60Hz ±2Hz

    Ambient temperature

    -10°C~+40°C

    Relative humidity

    35%~85%