    Stationary Meter Test System With 0.01 Class Accuracy And Optional Standard Meter

    Ask Lasest Price
    Brand Name : GENY
    Model Number : YC1893R
    Certification : ISO, CE
    Payment Terms : L/C, T/T, D/P
    Supply Ability : 100/Year
    • Product Details
    • Company Profile

    Stationary Meter Test System With 0.01 Class Accuracy And Optional Standard Meter

    Stationary Meter Test System with 0.01 Class Accuracy and Optional Standard Meter

    YC-1893R series of three-phase electrical energy standard calibration device is the company developed with the international advanced level of similar devices, high-level three-phase standard devices, the overall accuracy level of 0.01 level, is designed for national and provincial and municipal metrology institutes, the Institute of Electricity, electric energy metering products production plants and other units tailored to the high level of the standard electrical energy devices, mainly for the establishment of the main standard or used to test the standard meter Working standard

    Specification

    ParameterDescription
    Accuracy Class0.01 Class
    Optional Standard MetersCOM3003, RX-31, K8e, etc.
    Number of Simultaneous Standard Meters3 or 6 pieces (up to 12 meter positions as per customer requirements)
    Voltage Range (Phase-Neutral)3×30V to 480V
    Power of Voltage Output3×200VA
    Voltage Resolution0.001%
    Voltage Stability0.005%/120s
    Load Change Rate0.01% (entire linear load range)
    Voltage Distortion≤ 0.05 %
    Current Range3×1mA to 120A (up to 230A current as per customer requirements)
    Power of Current Output3×300VA
    Current Resolution0.001%
    Current Stability0.005%/120s
    Current Distortion≤0.05 %
    Phase Adjustment Range0° to 360°
    Phase Resolution0.01°
    Frequency Adjustment Range45Hz to 65Hz
    Frequency Resolution0.001Hz
    Power Stability0.020~120A: 0.005%/120s 0.005~0.020A: 0.01%/120s 0.003~0.005A: 0.02%/120s
    Harmonic Output1st to 64th harmonics, content: ≤40%
    Error DisplayMethod: LED display Number: One display window per meter position
    Operating EnvironmentPower supply: 3P4W 3×380V±10%, 50Hz±2Hz Ambient temperature: 20℃±5℃ Ambient humidity: 50%R.H±15%R.H

    Features

    • Measurement methods: active power, reactive power, active energy, reactive energy, start-up, latent test
    • Measurement basic error, average error, standard deviation, 24h variation
    • Voltage effect, frequency effect, harmonic effect (1-64th), phase sequence effect test
    • Measurement of current and voltage at the same time, but different constants and levels of the standard energy meter, can automatically identify the standard meter constants
    • It has current open circuit and voltage short circuit protection function.
    • Automatic and manual operation modes
    • Processing and organizing of error data, data storage and online output are automatically realized by computer software.
    • Excellent data management and statistical functions, according to the user needs to print a variety of formats of the report, support bar code input
    • Adopt linear power amplifier circuit, power supply after special treatment, device frequency range without frequency beat phenomenon.
    • Comprehensively support IR46 standard test and JJG597 latest regulations test requirements.
    • Beautiful and practical appearance structure.
    • Translated with DeepL.com (free version)

    Special Features

    • Forward and reverse active, forward and reverse reactive power error test
    • SW-5D precision time base source can measure the daily timing error of power meter.
    • Communication test, satellite and computer calibration
    • Calibration constants (pulse counting, time, starting and stopping power in three ways)
    • Time period switching, demand cycle, demand value error test
    • Influence quantity test
    • Voltage unbalance, high harmonics
    • Interference test
    • Voltage dips, short-term interruptions
    • Translated with DeepL.com (free version)

    Stationary Meter Test System With 0.01 Class Accuracy And Optional Standard Meter

    Quality Stationary Meter Test System With 0.01 Class Accuracy And Optional Standard Meter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou GENY Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)