Sign In | Join Free | My burrillandco.com
Home > Stationary Meter Test Bench >

GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability

Guangzhou GENY Electric Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability from wholesalers
     
    Buy cheap GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability from wholesalers
    • Buy cheap GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability from wholesalers

    GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability

    Ask Lasest Price
    Brand Name : GENY
    Model Number : YC1893D
    Certification : ISO, CE
    Price : negotiate rates
    Payment Terms : T/T,L/C,D/P,T/T
    Supply Ability : 5 sets / 1 months
    Delivery Time : 6~8weeks
    • Product Details
    • Company Profile

    GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability

    GENY YC1893D – Smart Automatic Meter Test System



    The GENY YC1893D Meter Test System is a high-performance, fully automatic meter testing and calibration solution designed for both single-phase and three-phase electric energy meters. It is ideal for applications in:

    • Electric energy meter manufacturers

    • Power utilities

    • National metrology laboratories

    • Quality inspection and measurement departments

    • Industrial enterprises


    Cutting-Edge Technology & Modular Design



    GENY’s meter test systems integrate advanced electronic measurement technology with a modular system architecture. By combining different reference standards and high-precision power amplifiers, the system can be configured to meet a wide range of customer needs.



    System Components


    • Three-phase power source for generating stable, programmable test conditions

    • Three-phase reference standard meter for precise measurement

    • Meter suspension racks supporting both single-phase and three-phase meter testing

    • Smart meter function testing tools, including:

      • Fixed voltage outputs

      • Optical probe interface

      • Relay control testing

      • Optional ripple control box

    • Control PC and dedicated software for full system automation

    • Additional components as required for specific test cases


    Specifications


    Technical spec.

    YC1893D-ICT-6

    YC1893D-ICT-12

    YC1893D-ICT-24

    YC1893D-ICT-48

    Number of meter positions equipped ICT

    6

    12

    24

    48

    Accuracy class of ICT

    0.05 / 0.01

    Accuracy

    0.05

    Power Source

    YCS-103-250

    YCS-103-600

    YCS-103-1200

    YCS-103-2500

    Standard Meter

    SZ03A-K6 / SZ03A-K8 (customized)

    Scanning Head

    YCG-S Series

    Voltage


    Test voltage output(Phase-Neutral)

    3x(24V~288V)(or customized)

    Power of the voltage output

    Max. 3x100VA

    Max. 3x250VA

    Max.

    3x500VA

    Max.

    3x1000VA

    Resolution

    Better than 0.01% of full scale value of range

    Setting accuracy

    Better than 0.05% at the final range value

    Stability

    Better than 0.005% /h (integration time 150s)

    Load regulation from 0~max. load

    Better than 0.01%

    Distortion factor

    Better than 0.3% for linear resistance load

    Harmonic

    2nd~21st free programmable

    Current


    Test current output

    3x(1mA~100A)

    Power of the current output

    Max. 3x150VA

    Max. 3x350VA

    Max. 3x750VA

    Max. 3x1500VA

    Resolution

    Better than 0.01% of full scale value of range

    Setting accuracy

    Better than 0.05% at the final range value

    Stability

    Better than 0.005% /h (integration time 150s)

    Load regulation from 0~max. load

    Better than 0.01%

    Distortion factor

    Better than 0.3% for linear resistance load

    Harmonic

    2nd~21st free programmable

    Phase angle


    Range

    0~360⁰

    Resolution

    0.01⁰

    Setting accuracy

    0.1⁰

    Frequency


    Range

    45Hz~65Hz

    Resolution

    0.01Hz

    Error display


    Type of error display

    Red LED

    Resolution of error displays

    8 digitals

    Other


    Voltage supply

    3x220/380V±10%(or customized)

    50/60Hz ±2Hz

    Ambient temperature

    -10°C~+40°C

    Relative humidity

    35%~85%

    GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability

    GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability

    GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability

    Quality GENY YC1893D Smart Automatic Meter Test System with 3 × (24V – 300V) Test Voltage Output and 0.005%/h Stability for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou GENY Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)