| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | GENY |
| Model Number : | YC-1891D |
| Certification : | ISO, CE |
| Price : | negotiation |
| Payment Terms : | L/C,T/T,D/P |
| Supply Ability : | 100/Year |
| Delivery Time : | 4-6weeks |
Voltage | ||||
Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) | |||
Power of the voltage output | Max. to 3x500VA | |||
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Current | ||||
Test current output | 3x(1mA~100A) | |||
Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Phase angle | ||||
Range | 0~360⁰ | |||
Resolution | 0.01⁰ | |||
Setting accuracy | 0.1⁰ | |||
Frequency | ||||
Range | 45Hz~65Hz | |||
Resolution | 0.01Hz | |||
Error display | ||||
Type of error display | Red LED | |||
Resolution of error displays | 8 digitals | |||
Other | ||||
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz | |||
Ambient temperature | -10°C~+40°C | |||
Relative humidity | 35%~90% | |||
>1. >Installing the ICT in each meter position to test three-phase meters with closed links between the current and voltage measuring circuits(I-P links)
>2. >The meter test system can measure mechanical meter, electronic mechanical meters and electronic meter by ways of automatic, semi-automatic or manual operation.
>3. >Meters under testing: 3P4W, 3P3W, 1P2W
>4. >Testing mode: active power, reactive power, cross connected reactive power
>5. >Simultaneously measure meters with same specifications but different meter constants
>6. >Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.
>7. >Starting test and creeping test
>8. >With the protection function of overload, short voltage circuit and open current circuit.
>9. >The swing together of the scanning heads simplifies the control.
>10. >Aluminum alloy material, light and strong and corrosion resistant
>11. >The testing software with friendly Windows 2000 /XP /7 /8 /10 operation system, includes functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test etc,.
>1. >Forward and reverse active, Forward and reverse reactive error test
>2. >SW-5D precise time reference source for testing the energy meter daiy time error.
>3. >Communication test and time calibration with speaker.
>4. >Check constant (pulse counting,time, demand indication error test)
>5. >Time switch, demand period and demand indication error test.
>6. >Register indication and register combination error test.
>7. >Four quadrant reactive power test
>8. >Power consumption test(optional).
>9. >The voltage and current loop of measured meter can be connected together(optional)
>10. >Tilt impact test(optional)
>11. >prepayment meter test(optional)
Current range | 3×(10mA – 120A) |
Accuracy | 0.05 (100mA – 120A) |
Ration | 1:1 (primary current = secondary current) |
Frequency range | 45Hz – 65Hz |
Output burden range | 3×0.6V (max) |
Output power | 3×60VA (max) |
Communication port | RS-485 |
Power supply | +/- 12VDC |
Power consumption | 20 VA (max) |
Operation temperature | - 10°C … +50°C |
Storage temperature | - 20°C … +60°C |
Dimension (H × W × D) | 290mm×275mm×296mm |
Wight | approx.17kg |

|