Sign In | Join Free | My burrillandco.com
Home > Stationary Meter Test Bench >

Three Phase Stationary Meter Test Bench

    Buy cheap Three Phase Stationary Meter Test Bench from wholesalers
     
    Buy cheap Three Phase Stationary Meter Test Bench from wholesalers
    • Buy cheap Three Phase Stationary Meter Test Bench from wholesalers

    Three Phase Stationary Meter Test Bench

    Ask Lasest Price
    Brand Name : GENY
    Model Number : YC-1893D
    Certification : ISO, CE
    Payment Terms : L/C, D/P, T/T, D/A
    Supply Ability : 10 pcs/ 3 months
    Delivery Time : 8 ~10weeks
    • Product Details
    • Company Profile

    Three Phase Stationary Meter Test Bench

    Professional Three-Phase Stationary Meter Test Bench for Electric Energy Meter Testing

    Stationary Three Phase Meter Test Bench


    The YC1893D meter test system is a full-automatic test system for testing and calibration of both single-phase and three-phase electric energy meters, which composes of:

    • Three-phase Power source
    • Three-phase Reference standard meter
    • Meter suspension test racks for testing of both 1-phase/3-phase meters
    • Smart meter function test system (fixed voltages, optical probe, relay control test and ripple control box as option)
    • Other necessary parts
    • PC and software controlling the whole system


    The YC1893D meter test system is fully compliant with the IEC 60736 standard and is suitable for testing meters according to the following standards:

    • IEC 62052-11 and IEC 62053-11, -21, -22, -23, -24
    • IEC 62056
    • EN 50470-1, EN 50470-2, EN-50470-3
    • IEC 61010


    Features


    • The meter test system can measure mechanical meters, electronic mechanical meters and electronic meter by the way of automatic, semi-automatic or manual operation.
    • Aluminium alloy material, light and strong and corrosion resistant.
    • Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.
    • The swing together of the scanning heads simplifies the control.
    • Fully automatic completion of the following tests:
      • Accuracy test in all four quadrants (active, reactive and apparent energy)
      • Repeatability of error test
      • Creep test (No-load test)
      • Starting current test
      • Dial test (Register test)
      • Meter constant test
      • Influence quantity test (voltage, voltage unbalance, frequency, harmonic distortion, reverse phase sequence.)
      • Calibration of reference standard meter having lower accuracy than the employed reference standard
      • Pre-warming
      • Dips and Interruptions
      • Testing single-phase meters under tampered conditions
      • Sub Harmonics as per IEC standards
      • Odd Harmonics as per IEC standards
    • Measuring different constants of meters synchronously.
    • With the protection function of overload, short voltage circuit and open current circuit.

    Technical specification


    The test bench is multiple positions up to 24 meters, 0.02% of accuracy class Three-phase Meter Test System with ICTs, with multiple serial port communication system for parallel communication for testing of smart meters.


    • Power Supply


    Voltage3x230 / 400 V ±10%, 50 / 60 Hz ±2 Hz
    Frequency50 Hz ±15%
    Power capacity> 6 kVA
    Power efficient(at full load)≥85%
    Ambient temperature-10 °C -- +40 °C
    Relative humidity35% - 85%

    • Power Source


    Voltage
    Test voltage output (Phase-Neutral)3x(24 – 300 V)
    Power of the voltage output3×1000VA
    ResolutionBetter than 0.01% of full scale value of range
    Setting accuracyBetter than 0.05% at the final range value
    StabilityBetter than 0.005%/h (integration time 150 s)
    Load regulation from 0-max. load< 0.01%
    Distortion factor< 0.3% for linear resistance load
    Harmonics2nd – 41st free programmable
    Current
    Test current output1 mA – 120 A
    Power of the current output3×2000VA
    ResolutionBetter than 0.01% of full scale value of range
    Setting accuracyBetter than 0.05% at the final range value
    StabilityBetter than 0.005%/h (integration time 150 s)
    Load regulation from 0-max. load< 0.01%
    Distortion factor< 0.3% for linear resistance load
    Harmonics2nd – 41st free programmable
    Phase angle
    Range0 -- 360°
    Resolution0.01°
    Setting accuracy0.1°
    Frequency
    Range45 Hz – 65 Hz
    Resolution0.01 Hz

    Structural diagram of stationary meter test bench

    Three Phase Stationary Meter Test Bench
    Three Phase Stationary Meter Test Bench
    Three Phase Stationary Meter Test Bench
    Three Phase Stationary Meter Test Bench
    *If you want to know more please check our official website:http://www.genymetertestequipment.com/
    Quality Three Phase Stationary Meter Test Bench for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou GENY Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)