| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | GENY |
| Model Number : | YCS-103 |
| Certification : | ISO, CE |
| Price : | negotiate rates |
| Payment Terms : | T/T,L/C,D/P,T/T |
| Supply Ability : | 5 sets / 1 months |
| Delivery Time : | 6~8weeks |
>
Max 21 Times Harmonic Free High Precision Three Phase Energy Stationary Power Source
| Parameter | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
| Voltage | ||||
| Test Voltage Output (Phase-Neutral) | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized |
| Power of the Voltage Output | 3×100VA | 3×250VA | 3×500VA | 3×1000VA |
| Resolution | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range |
| Setting Accuracy | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value |
| Stability | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) |
| Load Regulation from 0-max. Load | < 0.01% | < 0.01% | < 0.01% | < 0.01% |
| Distortion Factor | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load |
| Harmonics (2nd – 21st) | Free programmable | Free programmable | Free programmable | Free programmable |
| Current | ||||
| Test Current Output | 3×(1mA – 100A) | 3×(1mA – 100A) | 3×(1mA – 100A) | 3×(1mA – 100A) |
| Power of the Current Output | 3×150VA | 3×350VA | 3×750VA | 3×1500VA |
| Resolution | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range |
| Setting Accuracy | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value |
| Stability | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) |
| Load Regulation from 0-max. Load | < 0.01% | < 0.01% | < 0.01% | < 0.01% |
| Distortion Factor | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load |
| Harmonics (2nd – 21st) | Free programmable | Free programmable | Free programmable | Free programmable |
| Phase Angle | ||||
| Range | 0 -- 360° | 0 -- 360° | 0 -- 360° | 0 -- 360° |
| Resolution | 0.01° | 0.01° | 0.01° | 0.01° |
| Setting Accuracy | 0.1° | 0.1° | 0.1° | 0.1° |
| Frequency | ||||
| Range | 45Hz – 65Hz | 45Hz – 65Hz | 45Hz – 65Hz | 45Hz – 65Hz |
| Resolution | 0.01Hz | 0.01Hz | 0.01Hz | 0.01Hz |
| Voltage Supply | ||||
| Voltage Supply | 3×220/380V±10% or customized | 3×220/380V±10% or customized | 3×220/380V±10% or customized | 3×220/380V±10% or customized |
| Frequency | 50/60Hz±2Hz | 50/60Hz±2Hz | 50/60Hz±2Hz | 50/60Hz±2Hz |
| Operating Conditions | ||||
| Ambient Temperature | -10°C -- +40°C | -10°C -- +40°C | -10°C -- +40°C | -10°C -- +40°C |
| Relative Humidity | 35-- 85% | 35% -- 85% | 35% -- 85% | 35% -- 85% |




*If you want to know more please check our official website:http://www.genymetertestequipment.com/
|