Sign In | Join Free | My burrillandco.com
Home > Portable Meter Test System >

45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities

Guangzhou GENY Electric Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities from wholesalers
     
    Buy cheap 45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities from wholesalers
    • Buy cheap 45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities from wholesalers

    45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities

    Ask Lasest Price
    Brand Name : GENY
    Model Number : YC99T-3C/5C
    Certification : ISO, CE
    Price : negotiate rates
    Payment Terms : T/T, L/C, D/P, T/T
    Supply Ability : 5 sets / 1 months
    Delivery Time : 6~8weeks
    • Product Details
    • Company Profile

    45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities

    Portable Meter Test System YC99T-3C/5C for Universities and Related Research Institutions

    Description:


    It is used in the measurement testing center of the grid companies, measurement department of power supply companies and power plants,
    national measurement testing institutions and metrology inspection departments, measurement testing departments of medium-sized enterprises, such as railway and petrochemical. Also, it can be used by the manufacturers of energy meters, includes its production, research and development, testing departments, as well as in universities and related research institutions, specialized laboratories.
    The meters user can calibrate including : Single-phase active energy meter, three-phasethree-wire active energy meter, three-phase three-wire composite meter, three-phasefour-wire active energy meter, three-phase four-wire composite meter, three-phasethree-wire sine reactive energy meter, three-phase four-wire sine reactive energy metertwo elements 60°reactive energy meter, two elements 90° reactive energy meter, andthree elements 90° reactive energy meter .

    Main functions:


    • It can test various single and three phase electronic and mechanical meters;
    • It can automatically or manually test 1ph or 3ph meters’: basic error, creeping test, starting test, standard deviation and etc., the testing plan can be fixed by customers; . It can execute the influence test includes: voltage influence, frequency influence, harmonic influence, reverse phase sequence influence, unbalance voltage influence test;
    • Support DLTN645 communication protocol, and can execute some tests for multiNfunctions energy meters;
    • More output terminals for more operations: RS232, RS485, extend I/O, Ethernet, USB, wifi and etc.;
    • Output 2~63 harmonics
    • 8 inch touchscreen and friendly operation system;
    • It can test 3 pcs meters max.

    Specifications:


    Model No.YC99T-3C
    Meter Position / Accuracy3 / 0.05
    AC Voltage output
    Range57.7V,100V, 220V, 380V,660
    Adjustment Range(0-120)%RG (RG is Range)
    Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG
    Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
    Distortion≤0.2% (Non capacitive load)
    Max Output load20VA/phase
    Measurement Accuracy±0.05%RG(0.05cl), ±0.1%RG(0.1cl)
    AC Current output
    Range0.05A,0.2A,1A,5A,16.67A,50A
    Adjust Range(0-120)%RG (RG is Range)
    Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG
    Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
    Distortion≤0.2% (Non capacitive load)
    Max Output load50VA(50A range)
    Measurement Accuracy±0.05%RG(0.05cl), ±0.1%RG(0.1cl)
    Power output
    Stability0.01%/2min(0.05cl), 0.02%/2min(0.1cl)
    Active, Reactive power accuracy±0.05%RG
    Phase output
    Output adjusting range0 ~ 359.99°
    Output adjusting power10°,1°,0.1°,0.01°optional
    Resolution0.01.
    Measurement accuracy±0.05.
    Power factor output
    Adjusting range-1~0~+1
    Measuring resolution0.0001
    Measurement accuracy±0.0005
    Frequency output
    Adjusting range40Hz – 70Hz
    Output adjusting resolution1Hz, 0.1Hz, 0.01Hz, 0.001Hz optional
    Resolution0.001Hz
    Accuracy±0.002Hz
    Harmonic setting
    Harmonic order2nd~63rd
    Harmonic amplitude0~40%
    Harmonic angle0 °~359.00°
    Harmonic set error2nd ~ 31st :≤±0.1%, 32nd~63rd : ≤±0.2%
    Energy error measurement
    Active energy basic error limit±0.05%RD(voltage30V~660V,current0.02A~60A,PF≥0.5)
    Reactive energy basic error limit±0.1%RD(voltage30V~660V,current0.02A~60A,PF≥0.5)
    Standard crystal
    Frequency accuracy±0.5ppm (leave factory@25℃)
    Frequency stability±0.1ppm,-20℃~+70℃
    Energy pulse input
    Number of energy pulse input3 channels active, 3 channels reactive
    General parameters
    Power supplyAC220V±15% or 110V±15%
    Frequency50Hz~60Hz
    Consumption60VA~1000VA
    Environment condition20℃ ~ 30℃,relative humidity≤85%
    Storage environment-20℃~50℃
    Size & Weight600mm(L)X400mm(W) X266mm(H), 30kg
    Model No.YC99T-5C
    Meter Position / Accuracy3 / 0.05cl
    AC Voltage output
    Range57.7V,100V, 220V, 380V
    Adjustment Range(0-120)%RG (RG is Range)
    Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG
    Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
    Distortion≤0.2% (resistance load)
    Max Output load20VA/phase
    Measurement Accuracy±0.05%RG(0.05cl), ±0.1%RG(0.1cl)
    AC Current output
    Range0.05A,0.2A,1A,5A,20A,100A
    Adjust Range(0-120)%RG (RG is Range)
    Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG(optional)
    Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
    Distortion≤0.2% (Non capacitive load)
    Max Output load100VA(100A range)
    Measurement Accuracy±0.05%RG(0.05cl), ±0.1%RG(0.1cl)
    Power output
    Stability0.01%/2min(0.05cl), 0.02%/2min(0.1cl)
    Active, Reactive power accuracy±0.05%RG
    Phase output
    Output adjusting range0 ~ 359.99°
    Output adjusting power10°,1°,0.1°,0.01°optional
    Resolution0.01.
    Measurement accuracy±0.05.
    Power factor output
    Adjusting range-1~0~+1
    Measuring resolution0.0001
    Measurement accuracy±0.0005
    Frequency output
    Adjusting range45Hz – 70Hz
    Output adjusting resolution1Hz, 0.1Hz, 0.01Hz, 0.001Hz
    Resolution0.001Hz
    Accuracy±0.002Hz
    Harmonic setting
    Harmonic order2nd~63rd
    Harmonic amplitude0~40%
    Harmonic angle0 °~359.99°
    Harmonic set error2nd ~ 31st :≤±0.1%, 32nd~63rd : ≤±0.2%
    Energy error measurement
    Active energy basic error limit±0.05%RD(voltage30V~380V,current0.02A~120A,PF≥0.5)
    Reactive energy basic error limit±0.1%RD(voltage30V~380V,current0.02A~120A,PF≥0.5)
    Standard crystal
    Frequency accuracy±0.5ppm (leave factory@25℃)
    Frequency stability±0.1ppm,-20℃~+70℃
    Energy pulse input
    Number of energy pulse input3 channels active, 3 channels reactive
    General parameters
    Power supplyAC220V±15% or 110V%15%
    Frequency50Hz~60Hz
    Consumption60VA~1000VA
    Environment condition20℃ ~ 30℃,relative humidity≤85%
    Storage environment-20℃~50℃
    Size & Weight600mm(L)X400mm(W) X266mm(H), 48kg
    45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities
    45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities
    *If you want to know more please check our official website:http://www.genymetertestequipment.com/

    Quality 45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou GENY Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)